Dwelling Load Calculator NEC Article 220

Single-family dwelling service/feeder load calculation. Select calculation method below.

Which method should I use?
Standard (Part III) — Required for new construction. Uses individual demand factors per load type.
Optional (Part IV) — Allowed for existing dwellings with 100A+ service per 220.82. Uses a simplified demand factor on total connected load. Often yields a lower result.

General Lighting & Receptacles 220.12

3 VA per sq ft per NEC 220.12

Small Appliance & Laundry 220.52

1,500 VA each per 220.52(A)

1,500 VA each per 220.52(B)

Fixed Appliances 220.53

Enter nameplate VA for each. If 4+ fixed appliances, 75% demand factor applies per 220.53.

NEC 220.55 Table demand applies

Min 5,000 VA per 220.54

Trash compactor, built-in microwave, etc.

Heating & Cooling 220.60

Only the larger of heating or cooling is used (non-coincident loads per 220.60).

Nameplate VA or amps × 240V

Total of all fixed electric heat strips

By clicking Apply, you acknowledge that results are for reference only and must be verified by a qualified electrician against the current National Electrical Code and local amendments.

Calculated Demand Load
Service Amps (at 240V)
Recommended Service Size
ItemVA

For reference only. Verify all results with the current NEC and local amendments. See Terms of Use.